Skip to product information
1 of 3

Kernal KN-4003B Philips Narrow Band UVB Lamp for Vitiligo — Home Use Portable

Kernal KN-4003B Philips Narrow Band UVB Lamp for Vitiligo — Home Use Portable

Regular price €240,00 EUR
Regular price Sale price €240,00 EUR
Sale Sold out
Shipping calculated at checkout.

Handheld 311nm Narrowband UVB Phototherapy for Home and Travel

The KN-4003B is a handheld, portable narrowband UVB phototherapy device built around a genuine Philips 311nm UVB lamp. Designed specifically for home use, it combines one-key operation with a compact, lightweight form factor, making it easy for patients to manage their own phototherapy sessions outside a clinical setting.

Certification: FDA 510K cleared, CE MDR

Indications

The KN-4003B is positioned for phototherapy workflows involving:

  • Vitiligo
  • Psoriasis
  • Eczema
  • Pityriasis rosea
  • Dermatitis

Treatment protocols and suitability should be determined by the treating physician. This device is intended for use as directed by a healthcare provider for at-home phototherapy.

Light Source

Philips 311nm Narrowband UVB Lamp
The device uses an original Philips 9W UVB 311nm PL-S 2P/01 narrowband lamp, known for stability and long usage life, rated for more than 1,000 hours of operation. A built-in reflector increases irradiation efficiency, supporting effective treatment with the reduced side-effect profile associated with narrowband UVB light.

Key Features

One-Key Operation
A small, lightweight design makes the device easy for patients to carry, with simple one-key start operation that requires no complex setup.

Handheld, Flexible Positioning
Handheld use allows the treatment site to be targeted flexibly, adapting to different areas of the body as needed.

Anti-UV Protective Goggles
Professional anti-UV goggles are included to protect the eyes from ultraviolet radiation during treatment sessions.

Unique Comb Design
A specially designed comb attachment doubles as a safe-distance guide and extends use beyond the body to scalp treatment, parting hair for more direct light contact.

Travel-Friendly
The device's compact size and light weight make it convenient to bring along when traveling, supporting continuity of treatment outside the home.

Technical Specifications

Spec Detail
Package size 390mm × 190mm × 100mm (L×W×H)
Radiant area 55cm² ± 10%
Operation mode Continuous operation with intermittent loading
Working distance 3cm ± 0.5cm
UVA wavelength range 320–400nm (peak 368nm ± 3nm)
NB-UVB wavelength range 311–312nm (peak 311nm ± 3nm)
Lamp life expectancy More than 1,000 hours
Certifications CE, FDA

Frequently Asked Questions

Is this device intended for home use?
Yes — the KN-4003B is specifically designed for home use, with one-key operation suited to personal, unsupervised sessions as directed by a physician.

What makes narrowband UVB different from broader UV light sources?
The 311nm narrowband wavelength is associated with effective treatment outcomes while carrying a reduced side-effect profile compared to broader-spectrum UV light.

What is the comb attachment for?
It serves as both a safe-distance guide during treatment and an applicator for scalp use, in addition to standard use on the body.

How long does the lamp last?
The Philips lamp is rated for more than 1,000 hours of usage life.

ONE (1) YEAR LIMITED DEPOT WARRANTY (EU/EEA — CE MDR Version)

1. Warranty Provider and Term

This warranty is provided and administered strictly by the manufacturer of this particular product, not by Medaza Europe, d.o.o. The manufacturer warrants to the original purchasing entity ("Buyer") — including hospitals, clinics, and other licensed medical institutions within the European Union / European Economic Area — that the hardware product sold shall be free from defects in materials and workmanship under normal clinical use for a period of one (1) year from the date of shipment. This warranty is provided in addition to, and does not affect, any statutory rights the Buyer may hold as a matter of applicable EU or national consumer or commercial law.

2. Depot-Only Return Procedure

Warranty service is strictly a depot-return process conducted directly by the manufacturer of this particular product.

  • First Step (Intake): To initiate a warranty claim, the Buyer must not contact the manufacturer directly. The Buyer must first contact Medaza Europe, d.o.o. by email at contacteurope2@medaza-platform.com.
  • Delegation: Upon receipt of the email, Medaza Europe, d.o.o. — acting in its capacity as distributor under Regulation (EU) 2017/745 (the Medical Device Regulation, "MDR") — will delegate and coordinate the direct connection between the manufacturer (or the manufacturer's designated EU importer of record) and the Buyer, facilitating return logistics and securing the required Return Merchandise Authorization (RMA) number.
  • Shipment: No shipments will be accepted by the manufacturer's facility without an active, authorized RMA number. The product must be securely packaged in its original packaging (or equivalent protective packaging), with all patient-identifying information removed or de-identified in accordance with Regulation (EU) 2016/679 (the General Data Protection Regulation, "GDPR") and applicable national data protection requirements prior to shipment, and shipped directly to the designated service facility of the manufacturer.

3. Allocation of Shipping Costs (Two-Way Shipping)

The Buyer assumes full financial responsibility for all shipping logistics, packaging, handling fees, customs/tariffs, and insurance transit costs associated with the warranty claim. This includes:

  • Inbound Shipping: The cost to safely transport the product from the Buyer's facility to the designated service location of the manufacturer.
  • Outbound Shipping: The cost to return the repaired or replaced product from the manufacturer's facility back to the Buyer's designated location within the EU/EEA.

4. Field Safety Corrective Action & Systemic Defect Exception

The shipping cost allocation in Section 3 shall be waived solely in the event that the returned product is officially determined by the manufacturer, its EU importer of record, Medaza Europe, d.o.o., or an authorized regulatory body (e.g., a national Competent Authority such as JAZMP, or another EU/EEA Competent Authority) to be subject to a Field Safety Corrective Action (FSCA), Field Safety Notice, or a verified batch-wide Systemic Manufacturing Defect, in accordance with the vigilance and market surveillance requirements of MDR Articles 87–92. In such extraordinary circumstances, the manufacturer will cover standard two-way ground shipping costs.

5. Warranty Exclusions

This warranty does not cover:

  • Disposable clinical consumables (including but not limited to needles, sutures, applicators, and single-use accessories) once packaging is opened.
  • Damage caused by accident, abuse, liquid spills, improper sterilization or disinfection, neglect, patient misuse, or unauthorized modifications or repairs.
  • Damage resulting from use outside the manufacturer's labeled indications, intended purpose, or instructions for use (IFU), as defined under MDR Article 2.
  • Normal wear and tear, consumable component degradation (e.g., lamps, filters, probes), or cosmetic degradation that does not affect device function or safety.
  • Any device on which the Unique Device Identifier (UDI), serial number, or product identification label has been removed, altered, or defaced.

6. Incident Reporting and Vigilance

Nothing in this warranty limits or replaces the Buyer's independent obligation, as a healthcare institution or professional user, to report serious incidents or field safety issues involving this product in accordance with MDR Article 87. Reports should be directed to the manufacturer, to the manufacturer's designated EU importer of record, to Medaza Europe, d.o.o. as distributor, and, where required, to the relevant national Competent Authority (e.g., JAZMP) and/or logged via EUDAMED once the relevant EUDAMED modules become mandatory. Medaza Europe, d.o.o. will cooperate with the manufacturer, the importer of record, and Competent Authorities on any resulting vigilance investigation, corrective action, or reporting obligation.

7. Distributor Obligations Notice

 

For this product, Medaza Europe, d.o.o. acts solely as distributor under MDR Article 14; a separate, designated importer of record — not Medaza Europe, d.o.o. — fulfills the importer obligations under MDR Article 13 for this manufacturer's products. As distributor, Medaza Europe, d.o.o. confirms it verifies that the device bears the required CE marking and UDI, that it is accompanied by the manufacturer's required documentation and, where applicable, the importer's required labeling, and that appropriate storage and transport conditions are maintained while the product is under its responsibility. This warranty does not alter or diminish those statutory obligations, nor does it impose importer obligations on Medaza Europe, d.o.o.

Quantity

200 in stock

View full details