{"product_id":"kernal-kn-5000c-kernel-excimer-laser-308nm-phototherapy-system-for-psoriasis-and-vitiligo","title":"Kernal KN-5000C Kernel Excimer Laser 308nm Phototherapy System for Psoriasis and Vitiligo","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHigh-Intensity Targeted 308nm Excimer Phototherapy for Professional Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe KN-5000C is a professional 308nm excimer phototherapy system built around imported xenon chloride (XeCl) excimer light source technology. Designed for high-precision, targeted treatment of small to medium lesion areas, the KN-5000C delivers significantly higher irradiation intensity than conventional UVB or standard excimer devices, supporting shorter treatment cycles and fewer sessions.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\u003clabel style=\"box-sizing: border-box; display: inline-block; vertical-align: top; font-size: 16px; color: #333333;\"\u003eCertification:\u003c\/label\u003e \u003cspan style=\"box-sizing: border-box; display: inline-block; vertical-align: top; font-size: 16px; color: #333333;\"\u003eISO13485, FDA, CE MDR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eIndications\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThe KN-5000C is positioned for phototherapy workflows involving:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eVitiligo\u003c\/li\u003e\n\u003cli\u003ePsoriasis\u003c\/li\u003e\n\u003cli\u003eEczema\u003c\/li\u003e\n\u003cli\u003ePityriasis rosea\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eTreatment protocols and suitability should be determined by the treating physician based on lesion size, location, and patient condition.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLight Source\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eXeCl Excimer Light — 308nm\u003c\/strong\u003e\u003cbr\u003eThe system uses the latest generation of imported xenon chloride gas light source, continuously emitting high-intensity single-frequency 308nm excimer light with a stable waveband and pure spot output — designed to maximize treatment efficiency per session.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eWhy Intensity Matters: Comparative Output\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eDevice Type\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOutput Intensity\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRelative Therapeutic Effect\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e308nm UV lamp (home use)\u003c\/td\u003e\n\u003ctd\u003e3–5 mW\/cm²\u003c\/td\u003e\n\u003ctd\u003e★\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e311nm NB-UVB\u003c\/td\u003e\n\u003ctd\u003e6–10 mW\/cm²\u003c\/td\u003e\n\u003ctd\u003e★★\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraditional 308nm excimer laser\u003c\/td\u003e\n\u003ctd\u003e30 mW\/cm²\u003c\/td\u003e\n\u003ctd\u003e★★★★\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKN-5000C 308nm excimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 mW\/cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e★★★★★★★\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003eGreater illumination intensity translates directly to faster treatment effect and fewer required sessions compared to lower-intensity home-use or traditional excimer devices.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eKey Features\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHigh-Precision Targeted Treatment\u003c\/strong\u003e\u003cbr\u003eSuitable for small to medium treatment areas, the system is built for high targeting accuracy, making it easier to reach and treat specific lesion sites directly.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFlexible Treatment Handle\u003c\/strong\u003e\u003cbr\u003eA flexible treatment handle precisely controls the irradiation range, keeping light confined to the lesion and avoiding exposure to surrounding healthy skin.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAutomatic MED (Minimal Erythema Dose) Testing\u003c\/strong\u003e\u003cbr\u003eA built-in UV dosage scheme enables automatic six-spot skin phototoxicity testing, simplifying what is normally a complex process into an easy, patient-specific workflow for determining the appropriate treatment dose.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSix Interchangeable Shading Sheets\u003c\/strong\u003e\u003cbr\u003eSix different sizes of shading sheets are included, allowing the treatment area to be adapted to lesions of different sizes for more precise, efficient application.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDual Treatment Modes\u003c\/strong\u003e\u003cbr\u003eUsers can select between dose mode and time mode depending on treatment preference and protocol.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e8\" Full Touch Screen\u003c\/strong\u003e\u003cbr\u003eAn 8-inch TFT color touch screen with a user-friendly GUI is designed to make operation easier, safer, and more convenient to monitor during treatment.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eQuick-Connect Treatment Handle\u003c\/strong\u003e\u003cbr\u003eThe treatment handle uses a quick-connection design, making light source replacement faster and more convenient for ongoing clinical use.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpec\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation mode\u003c\/td\u003e\n\u003ctd\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC220V ±10%, 50Hz ±2% (output: AC100–240V, 50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power\u003c\/td\u003e\n\u003ctd\u003e160VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e8\" color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eXeCl excimer light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiation area\u003c\/td\u003e\n\u003ctd\u003e20cm² ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiation intensity\u003c\/td\u003e\n\u003ctd\u003e50 mW\/cm² ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source lifetime\u003c\/td\u003e\n\u003ctd\u003e≥500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime setting range\u003c\/td\u003e\n\u003ctd\u003e120S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, FDA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003eWho It's For\u003c\/h3\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eDermatology clinics\u003c\/li\u003e\n\u003cli\u003eHospital dermatology departments\u003c\/li\u003e\n\u003cli\u003eSpecialty phototherapy centers\u003c\/li\u003e\n\u003cli\u003eInstitutions treating localized vitiligo and psoriasis lesions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow is the KN-5000C different from standard NB-UVB or home-use UV devices?\u003c\/strong\u003e\u003cbr\u003eIt delivers up to 50 mW\/cm² of intensity — roughly 5–17x the output of home-use or standard NB-UVB lamps — supporting faster results and fewer treatment sessions for targeted lesions.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIs this suitable for whole-body treatment?\u003c\/strong\u003e\u003cbr\u003eNo — the KN-5000C is designed for small to medium, targeted lesion areas rather than whole-body phototherapy, which is better suited to a cabinet-style system.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat is MED testing and why does it matter?\u003c\/strong\u003e\u003cbr\u003eMED (Minimal Erythema Dose) testing determines the correct UV dose for an individual patient's skin. The KN-5000C automates this with a built-in six-spot test, simplifying dose calibration before treatment begins.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow long does the light source last?\u003c\/strong\u003e\u003cbr\u003eThe light source is rated for 500+ hours of use before replacement is needed.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eONE (1) YEAR LIMITED DEPOT WARRANTY (EU\/EEA — CE MDR Version)\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e1. Warranty Provider and Term\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty is provided and administered strictly by the manufacturer of this particular product, not by Medaza Europe, d.o.o. The manufacturer warrants to the original purchasing entity (\"Buyer\") — including hospitals, clinics, and other licensed medical institutions within the European Union \/ European Economic Area — that the hardware product sold shall be free from defects in materials and workmanship under normal clinical use for a period of one (1) year from the date of shipment. This warranty is provided in addition to, and does not affect, any statutory rights the Buyer may hold as a matter of applicable EU or national consumer or commercial law.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e2. Depot-Only Return Procedure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eWarranty service is strictly a depot-return process conducted directly by the manufacturer of this particular product.\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirst Step (Intake):\u003c\/strong\u003e To initiate a warranty claim, the Buyer must not contact the manufacturer directly. The Buyer must first contact Medaza Europe, d.o.o. by email at \u003ca href=\"mailto:contacteurope2@medaza-platform.com\"\u003econtacteurope2@medaza-platform.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelegation:\u003c\/strong\u003e Upon receipt of the email, Medaza Europe, d.o.o. — acting in its capacity as \u003cstrong\u003edistributor\u003c\/strong\u003e under Regulation (EU) 2017\/745 (the Medical Device Regulation, \"MDR\") — will delegate and coordinate the direct connection between the manufacturer (or the manufacturer's designated EU importer of record) and the Buyer, facilitating return logistics and securing the required Return Merchandise Authorization (RMA) number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipment:\u003c\/strong\u003e No shipments will be accepted by the manufacturer's facility without an active, authorized RMA number. The product must be securely packaged in its original packaging (or equivalent protective packaging), with all patient-identifying information removed or de-identified in accordance with Regulation (EU) 2016\/679 (the General Data Protection Regulation, \"GDPR\") and applicable national data protection requirements prior to shipment, and shipped directly to the designated service facility of the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e3. Allocation of Shipping Costs (Two-Way Shipping)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Buyer assumes full financial responsibility for all shipping logistics, packaging, handling fees, customs\/tariffs, and insurance transit costs associated with the warranty claim. This includes:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInbound Shipping:\u003c\/strong\u003e The cost to safely transport the product from the Buyer's facility to the designated service location of the manufacturer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutbound Shipping:\u003c\/strong\u003e The cost to return the repaired or replaced product from the manufacturer's facility back to the Buyer's designated location within the EU\/EEA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e4. Field Safety Corrective Action \u0026amp; Systemic Defect Exception\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe shipping cost allocation in Section 3 shall be waived solely in the event that the returned product is officially determined by the manufacturer, its EU importer of record, Medaza Europe, d.o.o., or an authorized regulatory body (e.g., a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) to be subject to a \u003cstrong\u003eField Safety Corrective Action (FSCA)\u003c\/strong\u003e, Field Safety Notice, or a verified batch-wide Systemic Manufacturing Defect, in accordance with the vigilance and market surveillance requirements of MDR Articles 87–92. In such extraordinary circumstances, the manufacturer will cover standard two-way ground shipping costs.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e5. Warranty Exclusions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eDisposable clinical consumables (including but not limited to needles, sutures, applicators, and single-use accessories) once packaging is opened.\u003c\/li\u003e\n\u003cli\u003eDamage caused by accident, abuse, liquid spills, improper sterilization or disinfection, neglect, patient misuse, or unauthorized modifications or repairs.\u003c\/li\u003e\n\u003cli\u003eDamage resulting from use outside the manufacturer's labeled indications, intended purpose, or instructions for use (IFU), as defined under MDR Article 2.\u003c\/li\u003e\n\u003cli\u003eNormal wear and tear, consumable component degradation (e.g., lamps, filters, probes), or cosmetic degradation that does not affect device function or safety.\u003c\/li\u003e\n\u003cli\u003eAny device on which the Unique Device Identifier (UDI), serial number, or product identification label has been removed, altered, or defaced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e6. Incident Reporting and Vigilance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eNothing in this warranty limits or replaces the Buyer's independent obligation, as a healthcare institution or professional user, to report serious incidents or field safety issues involving this product in accordance with MDR Article 87. Reports should be directed to the manufacturer, to the manufacturer's designated EU importer of record, to Medaza Europe, d.o.o. as distributor, and, where required, to the relevant national Competent Authority (e.g., JAZMP) and\/or logged via EUDAMED once the relevant EUDAMED modules become mandatory. Medaza Europe, d.o.o. will cooperate with the manufacturer, the importer of record, and Competent Authorities on any resulting vigilance investigation, corrective action, or reporting obligation.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e7. Distributor Obligations Notice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts solely as \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14; a separate, designated importer of record — not Medaza Europe, d.o.o. — fulfills the importer obligations under MDR Article 13 for this manufacturer's products. As distributor, Medaza Europe, d.o.o. confirms it verifies that the device bears the required CE marking and UDI, that it is accompanied by the manufacturer's required documentation and, where applicable, the importer's required labeling, and that appropriate storage and transport conditions are maintained while the product is under its responsibility. This warranty does not alter or diminish those statutory obligations, nor does it impose importer obligations on Medaza Europe, d.o.o.\u003c\/p\u003e","brand":"Kernal Medical","offers":[{"title":"Default Title","offer_id":48368330571963,"sku":"KERNAL009","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-16at12.03.53AM.png?v=1789543222","url":"https:\/\/eu.medaza-platform.com\/products\/kernal-kn-5000c-kernel-excimer-laser-308nm-phototherapy-system-for-psoriasis-and-vitiligo","provider":"Medaza Europe ","version":"1.0","type":"link"}