{"product_id":"anton-og5o-veterinary-oxygen-concentrator","title":"Anton-OG5O Veterinary Oxygen Concentrator","description":"\u003ch3 dir=\"auto\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eANTON-OG5O Veterinary Oxygen Concentrator \u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eThe ANTON-OG5O Veterinary Oxygen Concentrator delivers a safe, stable, and continuous supply of medical-grade oxygen for animal patients, engineered specifically for the demands of veterinary clinics, animal hospitals, and mobile practice settings. Manufactured under an \u003cstrong\u003eISO 13485-certified quality management system\u003c\/strong\u003e, this unit meets internationally recognized standards for medical device design, production, and safety — giving veterinary professionals added confidence in build quality and consistency. It integrates seamlessly with pet oxygen masks, oxygen chambers\/cages, veterinary ventilators, and anesthesia machines — making it a flexible core component for respiratory support, post-surgical recovery, emergency stabilization, and long-term oxygen therapy.\u003c\/p\u003e\n\u003ch4 dir=\"auto\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eKey Benefits\u003c\/h4\u003e\n\u003cul dir=\"auto\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eISO 13485-Certified Quality Assurance\u003c\/strong\u003e — Produced under a certified medical device quality management system, ensuring rigorous manufacturing controls, traceability, and consistent product reliability.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eConsistent, High-Purity Oxygen Output\u003c\/strong\u003e — Produces oxygen concentration of 93%±3%, ensuring dependable therapeutic value across a variable flow range of 0–5 L\/min, suitable for patients ranging from small companion animals to larger breeds.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eStable Delivery Pressure\u003c\/strong\u003e — Maintains an outlet pressure of 0.04–0.07 MPa, providing smooth, consistent flow compatible with a wide range of veterinary oxygen delivery accessories.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCompact, Clinic-Friendly Footprint\u003c\/strong\u003e — At 363 × 284 × 518 mm and just 17 kg net weight, the unit is easy to position, transport between rooms, or integrate into mobile veterinary units without requiring dedicated infrastructure.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eEnergy-Efficient Operation\u003c\/strong\u003e — Rated at only 420 VA, the unit is economical to run continuously, helping clinics manage operating costs during extended treatment or overnight monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"auto\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eProduct Features\u003c\/h4\u003e\n\u003col dir=\"auto\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-decimal flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eLow Noise Operation\u003c\/strong\u003e — Engineered for quiet performance, minimizing stress on animal patients and allowing comfortable use in exam rooms, recovery wards, and overnight care areas.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eEnergy Efficient\u003c\/strong\u003e — Low power draw supports cost-effective, sustainable clinic operations even under continuous use.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eContinuous Operation\u003c\/strong\u003e — Built for extended, uninterrupted duty cycles, making it suitable for surgical support, ICU-style monitoring, and prolonged oxygen therapy without performance degradation.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eHigh-Definition LCD Screen\u003c\/strong\u003e — Clear digital display allows real-time monitoring of flow rate and concentration output, giving veterinary staff precise control and confidence during treatment.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eISO 13485-Certified Manufacturing\u003c\/strong\u003e — Produced by a manufacturer holding ISO 13485 certification for medical device quality management systems.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4 dir=\"auto\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv dir=\"auto\" class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFlow Rate\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0–5 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eO₂ Concentration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e93%±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutlet Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.04–0.07 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e363 × 284 × 518 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e420 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eQuality Certification\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eISO 13485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4 dir=\"auto\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eRecommended Applications\u003c\/h4\u003e\n\u003cul dir=\"auto\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePost-operative recovery and anesthesia support\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eRespiratory distress and emergency stabilization\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eOxygen cage\/chamber therapy for small animals\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIntegration with veterinary ventilators and anesthesia workstations\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eRoutine oxygen supplementation in general practice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eONE (1) YEAR LIMITED DEPOT WARRANTY\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003e1. Warranty Provider and Term\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe warranty is provided and conducted strictly by \u003cb data-path-to-node=\"5\" data-index-in-node=\"51\"\u003ethe manufacturer of this particular product\u003c\/b\u003e, not by Medaza. \u003cb data-path-to-node=\"5\" data-index-in-node=\"111\"\u003eThe manufacturer of this particular product\u003c\/b\u003e warrants to the original purchasing entity (\"Buyer\") that the hardware products sold shall be free from defects in materials and workmanship under normal clinical use for a period of one (1) year from the date of shipment.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003e2. Depot-Only Return Procedure\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eWarranty service is strictly a depot-return process conducted directly by \u003cb data-path-to-node=\"7\" data-index-in-node=\"74\"\u003ethe manufacturer of this particular product\u003c\/b\u003e.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eFirst Step (Intake):\u003c\/b\u003e To initiate a warranty claim, the Buyer must not contact the manufacturer directly. \u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"105\"\u003eThe Buyer must contact Medaza first by email\u003c\/b\u003e at contacteurope2@medaza-platform.com.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eDelegation:\u003c\/b\u003e Upon receipt of the email, \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"39\"\u003eMedaza will delegate and coordinate the direct connection\u003c\/b\u003e between \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"105\"\u003ethe manufacturer of this particular product\u003c\/b\u003e and the Buyer, facilitating the return logistics and securing the required Return Merchandise Authorization (RMA) number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eShipment:\u003c\/b\u003e No shipments will be accepted by the manufacturer's facility without an active, authorized RMA number. The product must be securely packaged in its original packaging (or equivalent protective packaging) and shipped directly to the designated service facility of \u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"273\"\u003ethe manufacturer of this particular product\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003e3. Allocation of Shipping Costs (Two-Way Shipping)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe Buyer assumes full financial responsibility for all shipping logistics, packaging, handling fees, customs\/tariffs, and insurance transit costs associated with the warranty claim. This includes:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eInbound Shipping:\u003c\/b\u003e The cost to safely transport the product from the Buyer's facility to the designated service location of \u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"123\"\u003ethe manufacturer of this particular product\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eOutbound Shipping:\u003c\/b\u003e The cost to return the repaired or replaced product from the facility of \u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"92\"\u003ethe manufacturer of this particular product\u003c\/b\u003e back to the Buyer's designated location.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e4. Universal Recall \u0026amp; Systemic Defect Exception\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003eThe shipping cost allocation in Section 3 shall be waived solely in the event that the returned product is officially determined by \u003cb data-path-to-node=\"13\" data-index-in-node=\"132\"\u003ethe manufacturer of this particular product\u003c\/b\u003e, Medaza, or an authorized regulatory body (e.g., CE\/MDR) to be subject to a \u003cb data-path-to-node=\"13\" data-index-in-node=\"249\"\u003eUniversal Recall\u003c\/b\u003e, \u003cb data-path-to-node=\"13\" data-index-in-node=\"267\"\u003eSafety Alert\u003c\/b\u003e, or a verified batch-wide \u003cb data-path-to-node=\"13\" data-index-in-node=\"306\"\u003eSystemic Manufacturing Defect\u003c\/b\u003e. In such extraordinary circumstances, \u003cb data-path-to-node=\"13\" data-index-in-node=\"374\"\u003ethe manufacturer of this particular product\u003c\/b\u003e will cover standard two-way ground shipping costs.\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003e5. Warranty Exclusions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003eThis warranty does not cover:\u003c\/p\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eDisposable clinical consumables (including but not limited to needles, sutures, and catheters) once packaging is opened.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eDamage caused by accident, abuse, liquid spills, improper sterilization, neglect, or unauthorized modifications\/repairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eNormal wear and tear or cosmetic degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beijing Yafmed","offers":[{"title":"Default Title","offer_id":48123931852987,"sku":"ANTON002","price":469.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Image_20260709210621_278_317.jpg?v=1784763561","url":"https:\/\/eu.medaza-platform.com\/products\/anton-og5o-veterinary-oxygen-concentrator","provider":"Medaza Europe ","version":"1.0","type":"link"}