{"product_id":"anton-a600-multi-function-gas-anesthesia-system","title":"Anton-A600 Multi-Function Gas Anesthesia System","description":"\u003cp\u003e\u003cimg alt=\"\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eAnton-A600 Multi-Function Gas Anesthesia System\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003ePrecision Inhalant Anesthesia for Small Animal Research \u0026amp; Veterinary Use\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eThe ANTON-A600 is a fully integrated gas anesthesia system designed for veterinary clinics, research laboratories, and academic institutions performing procedures on mice, rats, nude mice, rabbits, and other small animals. Combining a vaporizer, air pump, negative-pressure waste gas recovery system, and tail-vein injection assist unit into a single compact platform, the A600 delivers precise, stable isoflurane anesthesia while minimizing lab footprint and gas consumption.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eCertification:\u003cmeta charset=\"utf-8\"\u003eISO 13485-Certified Manufacturing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eStable, high-precision vaporizer with adjustable isoflurane concentration output\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eSingle-circuit breathing pathway (non-rebreathing) to reduce dead space\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eThree-channel gas output — run multiple procedures or stations simultaneously\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFour high-precision flowmeters for accurate gas input\/output control\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eSealed, lockable vaporizer knob prevents accidental release\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eIntegrated negative-pressure waste gas recovery for induction chamber and imaging chamber, protecting lab personnel\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBuilt-in mouse restraint platform with dual (yellow\/white) transillumination for tail-vein injection assistance\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCompact, space-saving integrated design reduces tubing length and gas waste\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCompatible with standard cage-mount\/Selectatec-style vaporizers, including the Ibis 200 Isoflurane Vaporizer\u003c\/strong\u003e, for labs wanting to standardize on a widely-used, keyed-fill vaporizer across multiple stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003ePharmacology, anesthesia and injection procedures, molecular biology, and in vivo\/live animal imaging — suitable for dissection, injection, and surgical training on live small animals.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\" style=\"width: 100.104%; height: 333.094px;\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" style=\"width: 25.0526%; height: 19.5938px;\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" style=\"width: 74.5263%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 19.5938px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 19.5938px;\"\u003eAC 100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 19.5938px;\"\u003eGas Output\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 19.5938px;\"\u003e0–10 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 39.1875px;\"\u003eAnesthetic Concentration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 39.1875px;\"\u003e0.2%–6% adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 39.1875px;\"\u003eFilter Compatibility\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 39.1875px;\"\u003eActivated carbon or soda lime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 39.1875px;\"\u003eCompatible Anesthetic\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 39.1875px;\"\u003eIsoflurane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 19.5938px;\"\u003eUnit Dimensions\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 19.5938px;\"\u003e351 × 302 × 490 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 19.5938px;\"\u003eUnit Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 19.5938px;\"\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 39.1875px;\"\u003ePackaged Dimensions\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 39.1875px;\"\u003e550 × 520 × 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 19.5938px;\"\u003ePackaged Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 19.5938px;\"\u003e28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 25.0526%; height: 58.7812px;\"\u003eSystem Includes\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 74.5263%; height: 58.7812px;\"\u003eVaporizer ×1, Induction chamber ×1, Air pump ×1, Flowmeters ×4, Waste gas recovery canister ×1, Tail-vein injection assist unit ×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eONE (1) YEAR LIMITED DEPOT WARRANTY\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003e1. Warranty Provider and Term\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe warranty is provided and conducted strictly by \u003cb data-path-to-node=\"5\" data-index-in-node=\"51\"\u003ethe manufacturer of this particular product\u003c\/b\u003e, not by Medaza. \u003cb data-path-to-node=\"5\" data-index-in-node=\"111\"\u003eThe manufacturer of this particular product\u003c\/b\u003e warrants to the original purchasing entity (\"Buyer\") that the hardware products sold shall be free from defects in materials and workmanship under normal clinical use for a period of one (1) year from the date of shipment.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003e2. Depot-Only Return Procedure\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eWarranty service is strictly a depot-return process conducted directly by \u003cb data-path-to-node=\"7\" data-index-in-node=\"74\"\u003ethe manufacturer of this particular product\u003c\/b\u003e.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eFirst Step (Intake):\u003c\/b\u003e To initiate a warranty claim, the Buyer must not contact the manufacturer directly. \u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"105\"\u003eThe Buyer must contact Medaza first by email\u003c\/b\u003e at contacteurope2@medaza-platform.com.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eDelegation:\u003c\/b\u003e Upon receipt of the email, \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"39\"\u003eMedaza will delegate and coordinate the direct connection\u003c\/b\u003e between \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"105\"\u003ethe manufacturer of this particular product\u003c\/b\u003e and the Buyer, facilitating the return logistics and securing the required Return Merchandise Authorization (RMA) number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eShipment:\u003c\/b\u003e No shipments will be accepted by the manufacturer's facility without an active, authorized RMA number. The product must be securely packaged in its original packaging (or equivalent protective packaging) and shipped directly to the designated service facility of \u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"273\"\u003ethe manufacturer of this particular product\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003e3. Allocation of Shipping Costs (Two-Way Shipping)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe Buyer assumes full financial responsibility for all shipping logistics, packaging, handling fees, customs\/tariffs, and insurance transit costs associated with the warranty claim. This includes:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eInbound Shipping:\u003c\/b\u003e The cost to safely transport the product from the Buyer's facility to the designated service location of \u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"123\"\u003ethe manufacturer of this particular product\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eOutbound Shipping:\u003c\/b\u003e The cost to return the repaired or replaced product from the facility of \u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"92\"\u003ethe manufacturer of this particular product\u003c\/b\u003e back to the Buyer's designated location.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e4. Universal Recall \u0026amp; Systemic Defect Exception\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003eThe shipping cost allocation in Section 3 shall be waived solely in the event that the returned product is officially determined by \u003cb data-path-to-node=\"13\" data-index-in-node=\"132\"\u003ethe manufacturer of this particular product\u003c\/b\u003e, Medaza, or an authorized regulatory body (e.g., CE\/MDR) to be subject to a \u003cb data-path-to-node=\"13\" data-index-in-node=\"249\"\u003eUniversal Recall\u003c\/b\u003e, \u003cb data-path-to-node=\"13\" data-index-in-node=\"267\"\u003eSafety Alert\u003c\/b\u003e, or a verified batch-wide \u003cb data-path-to-node=\"13\" data-index-in-node=\"306\"\u003eSystemic Manufacturing Defect\u003c\/b\u003e. In such extraordinary circumstances, \u003cb data-path-to-node=\"13\" data-index-in-node=\"374\"\u003ethe manufacturer of this particular product\u003c\/b\u003e will cover standard two-way ground shipping costs.\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003e5. Warranty Exclusions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003eThis warranty does not cover:\u003c\/p\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eDisposable clinical consumables (including but not limited to needles, sutures, and catheters) once packaging is opened.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eDamage caused by accident, abuse, liquid spills, improper sterilization, neglect, or unauthorized modifications\/repairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eNormal wear and tear or cosmetic degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Beijing Yafmed","offers":[{"title":"Default Title","offer_id":48127760433339,"sku":"ANTON004","price":8359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-07-23at9.33.56PM.png?v=1784867652","url":"https:\/\/eu.medaza-platform.com\/products\/anton-a600-multi-function-gas-anesthesia-system","provider":"Medaza Europe ","version":"1.0","type":"link"}