{"title":"Endoscopic Accessories","description":null,"products":[{"product_id":"health-microport-disposable-injection-needles","title":"Health Microport Disposable Injection Needles","description":"\u003ch2 dir=\"ltr\"\u003eDisposable Endoscopic Injection Needle\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use | Sterile\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Endoscopic Injection Needle is a single-use endoscopic accessory designed for submucosal injection in the digestive tract. It combines a transparent outer tube, a precision three-blade needle tip, and an ergonomic micro-rotation handle to give endoscopists controlled, predictable needle deployment during diagnostic and therapeutic GI procedures.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTransparent tube body.\u003c\/strong\u003e The clear catheter lets the clinician see blood return, which helps confirm needle position before injection.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMicro-rotation handle.\u003c\/strong\u003e A fine-control rotation mechanism lets the operator extend and retract the needle smoothly and precisely, which supports safe insertion and withdrawal through the endoscope working channel.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThree-blade needle tip.\u003c\/strong\u003e The diamond-shaped cross-section gives a sharper, cleaner puncture with less tissue resistance.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each device is supplied sterile for one-time use. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eFor endoscopic submucosal injection of the digestive tract.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel Number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNeedle O.D.\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNeedle Length (mm)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTube O.D. (mm)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWorking Length (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHM\/106T-23\/4-2.4\/1800, 2300M\u003c\/td\u003e\n\u003ctd\u003e23G \/ 0.6 mm\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003e1800, 2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHM\/106T-23\/5-2.4\/1800, 2300M\u003c\/td\u003e\n\u003ctd\u003e23G \/ 0.6 mm\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003e1800, 2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHM\/106T-25\/4-2.4\/1800, 2300M\u003c\/td\u003e\n\u003ctd\u003e25G \/ 0.5 mm\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003e1800, 2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHM\/106T-25\/5-2.4\/1800, 2300M\u003c\/td\u003e\n\u003ctd\u003e25G \/ 0.5 mm\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003e1800, 2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable style=\"width: 100%; height: 254.719px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth scope=\"col\" style=\"width: 22.5708%; height: 19.5938px;\"\u003e \u003c\/th\u003e\n\u003cth scope=\"col\" style=\"width: 73.9957%; height: 19.5938px;\"\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.5708%; height: 39.1875px;\"\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9957%; height: 39.1875px;\"\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5708%; height: 19.5938px;\"\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9957%; height: 19.5938px;\"\u003e69518622HM\/106G4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5708%; height: 19.5938px;\"\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9957%; height: 19.5938px;\"\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5708%; height: 19.5938px;\"\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9957%; height: 19.5938px;\"\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 22.5708%; height: 78.375px;\"\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9957%; height: 78.375px;\"\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.5708%; height: 39.1875px;\"\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9957%; height: 39.1875px;\"\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5708%; height: 19.5938px;\"\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.9957%; height: 19.5938px;\"\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/106T-23\/4-2.4\/1800 2300M ┃ Needle O.D.: 23G (0.6 mm) ┃ Needle Length: 4 mm ┃ Tube O.D.: 2.4 mm ┃ Working Length: 1800 mm 2300 mm","offer_id":50525094936763,"sku":"HMP001-01","price":25.65,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/106T-23\/5-2.4\/1800 2300M ┃ Needle O.D.: 23G (0.6 mm) ┃ Needle Length: 5 mm ┃ Tube O.D.: 2.4 mm ┃ Working Length: 1800 mm 2300 mm","offer_id":50525094969531,"sku":"HMP001-02","price":25.65,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/106T-25\/4-2.4\/1800 2300M ┃ Needle O.D.: 25G (0.5 mm) ┃ Needle Length: 4 mm ┃ Tube O.D.: 2.4 mm ┃ Working Length: 1800 mm 2300 mm","offer_id":50525095002299,"sku":"HMP001-03","price":25.65,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/106T-25\/5-2.4\/1800 2300M ┃ Needle O.D.: 25G (0.5 mm) ┃ Needle Length: 5 mm ┃ Tube O.D.: 2.4 mm ┃ Working Length: 1800 mm 2300 mm","offer_id":50525095035067,"sku":"HMP001-04","price":25.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/69ef9e1a8c344b2cffce5219_screenshot-2026-09-21-at-8.05.06-pm_1790130175654.png?v=1790130545"},{"product_id":"disposable-polyp-snare","title":"Health Microport Disposable Polyp Snare","description":"\u003ch2 dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIb) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Polyp Snare is a single-use endoscopic accessory for removing polyps and other excess tissue from the digestive tract with high-frequency electric current. It is used together with an endoscope and comes in four loop shapes, two outer diameters, and four open widths, to suit different lesion sizes, shapes, and resection techniques.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedical-grade stainless steel wire rope.\u003c\/strong\u003e The snare loop is made from imported medical stainless steel wire rope that conducts current well and cuts evenly.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e360° rotating handle.\u003c\/strong\u003e The rotating handle lets the operator orient the loop precisely, which makes it easier to position and capture polyps.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFour loop shapes.\u003c\/strong\u003e Oval, hexagonal, semi-crescent hexagonal, and crescent knife shapes are available, so the clinician can match the snare to lesion morphology and procedure technique.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each snare is used once. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eUsed with an endoscope to remove polyps or other excess tissue in the digestive tract with high-frequency electric current.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-2423DT10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Oval\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-1823DT10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Oval\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-2423DL10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Hexagonal\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-1823DL10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Hexagonal\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-2423DB10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Semi-Crescent Hexagonal\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-1823DB10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Semi-Crescent Hexagonal\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-2423DC10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Crescent Knife\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/701-1823DC10 15 25 30 ┃ \u003cstrong\u003eOpen Width:\u003c\/strong\u003e 10 15 25 30 mm ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eWorking Length:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eShape:\u003c\/strong\u003e Crescent Knife\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/701GQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/701-2423DT10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 2.4 mm ┃ Working Length: 2300 mm ┃ Shape: Oval","offer_id":67589225971899,"sku":"HMP002-01","price":20.72,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/701-1823DT10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 1.8 mm ┃ Working Length: 2300 mm ┃ Shape: Oval","offer_id":67589226004667,"sku":"HMP002-02","price":20.72,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/701-2423DL10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 2.4 mm ┃ Working Length: 2300 mm ┃ Shape: Hexagonal","offer_id":67589226037435,"sku":"HMP002-03","price":20.72,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/701-1823DL10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 1.8 mm ┃ Working Length: 2300 mm ┃ Shape: Hexagonal","offer_id":67589226070203,"sku":"HMP002-04","price":20.72,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/701-2423DB10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 2.4 mm ┃ Working Length: 2300 mm ┃ Shape: Semi-Crescent Hexagonal","offer_id":67589226102971,"sku":"HMP002-05","price":20.72,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/701-1823DB10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 1.8 mm ┃ Working Length: 2300 mm ┃ Shape: Semi-Crescent Hexagonal","offer_id":67589226135739,"sku":"HMP002-06","price":20.72,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/701-2423DC10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 2.4 mm ┃ Working Length: 2300 mm ┃ Shape: Crescent Knife","offer_id":67589226168507,"sku":"HMP002-07","price":20.72,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/701-1823DC10 15 25 30 ┃ Open Width: 10 15 25 30 mm ┃ O.D.: 1.8 mm ┃ Working Length: 2300 mm ┃ Shape: Crescent Knife","offer_id":67589226201275,"sku":"HMP002-08","price":20.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-28at4.49.33PM.png?v=1790639582"},{"product_id":"health-microport-disposable-biopsy-forceps","title":"Health Microport Disposable Biopsy Forceps","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Biopsy Forceps are a single-use endoscopic accessory for taking tissue samples from the digestive and respiratory tracts under endoscopic observation. They come in two outer diameters with oval or alligator cup jaws, with or without a needle, to suit different endoscope channels and sampling needs.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eRigid quad-pole connection.\u003c\/strong\u003e The rigid four-link jaw structure opens and closes firmly, which makes tissue sampling easier and more reliable.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSharp, intact cutting edge.\u003c\/strong\u003e The jaw blades are precision-formed to give clean tissue separation with each bite.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eLarge-capacity cup.\u003c\/strong\u003e The oversized jaw cup collects an adequate sample in fewer passes.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eJaw options.\u003c\/strong\u003e Oval cup and alligator cup jaws are available, each with or without a center needle. The needle helps anchor the forceps on the tissue during sampling.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eRotatable handle .\u003c\/strong\u003e A synchronous rotating handle lets the operator orient the jaws precisely at the target site.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSmooth outer coating .\u003c\/strong\u003e A super-smooth coating on the shaft reduces wear on the endoscope working channel.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eTissue sampling from the digestive and respiratory tracts under endoscopic observation.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-A-23\/1600 2300 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 2300 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.8 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Oval Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e Without Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-B-23\/1600 2300 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 2300 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.8 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Oval Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e With Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-C-23\/1600 2300 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 2300 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.8 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Alligator Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e Without Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-D-23\/1600 2300 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 2300 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.8 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Alligator Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e With Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-A-18\/1200 1600 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1200 1600 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.0 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Oval Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e Without Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-B-18\/1200 1600 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1200 1600 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.0 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Oval Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e With Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-C-18\/1200 1600 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1200 1600 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.0 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Alligator Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e Without Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/101-D-18\/1200 1600 (S) ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1200 1600 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.0 mm ┃ \u003cstrong\u003eJaw Shape:\u003c\/strong\u003e Alligator Cup ┃ \u003cstrong\u003eNeedle:\u003c\/strong\u003e With Needle\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003e(S) = coated version\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/101FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/101-A-23\/1600 2300 (S) ┃ O.D.: 2.3 mm ┃ Length: 1600 2300 mm ┃ Endoscope Channel: 2.8 mm ┃ Jaw Shape: Oval Cup ┃ Needle: Without Needle","offer_id":67594988617915,"sku":"HMP003-01","price":9.62,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/101-B-23\/1600 2300 (S) ┃ O.D.: 2.3 mm ┃ Length: 1600 2300 mm ┃ Endoscope Channel: 2.8 mm ┃ Jaw Shape: Oval Cup ┃ Needle: With Needle","offer_id":67594988650683,"sku":"HMP003-02","price":9.62,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/101-C-23\/1600 2300 (S) ┃ O.D.: 2.3 mm ┃ Length: 1600 2300 mm ┃ Endoscope Channel: 2.8 mm ┃ Jaw Shape: Alligator Cup ┃ Needle: Without Needle","offer_id":67594988683451,"sku":"HMP003-03","price":9.62,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/101-D-23\/1600 2300 (S) ┃ O.D.: 2.3 mm ┃ Length: 1600 2300 mm ┃ Endoscope Channel: 2.8 mm ┃ Jaw Shape: Alligator Cup ┃ Needle: With Needle","offer_id":67594988716219,"sku":"HMP003-04","price":9.62,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/101-A-18\/1200 1600 (S) ┃ O.D.: 1.8 mm ┃ Length: 1200 1600 mm ┃ Endoscope Channel: 2.0 mm ┃ Jaw Shape: Oval Cup ┃ Needle: Without Needle","offer_id":67594988748987,"sku":"HMP003-05","price":9.62,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/101-B-18\/1200 1600 (S) ┃ O.D.: 1.8 mm ┃ Length: 1200 1600 mm ┃ Endoscope Channel: 2.0 mm ┃ Jaw Shape: Oval Cup ┃ Needle: With Needle","offer_id":67594988781755,"sku":"HMP003-06","price":9.62,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/101-C-18\/1200 1600 (S) ┃ O.D.: 1.8 mm ┃ Length: 1200 1600 mm ┃ Endoscope Channel: 2.0 mm ┃ Jaw Shape: Alligator Cup ┃ Needle: Without Needle","offer_id":67594988814523,"sku":"HMP003-07","price":9.62,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/101-D-18\/1200 1600 (S) ┃ O.D.: 1.8 mm ┃ Length: 1200 1600 mm ┃ Endoscope Channel: 2.0 mm ┃ Jaw Shape: Alligator Cup ┃ Needle: With Needle","offer_id":67594988847291,"sku":"HMP003-08","price":9.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-29at4.13.38PM.png?v=1791244952"},{"product_id":"disposable-guide-wire","title":"Health Microport Disposable Guide Wire","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Guide Wire is an endoscopic accessory used through an endoscope to navigate the digestive or urinary tract and to guide other medical devices into position. A hydrophilic coating, a soft atraumatic tip, and a high-visibility two-color spiral outer tube support smooth, controlled advancement during diagnostic and therapeutic procedures.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSuper-smooth hydrophilic coating.\u003c\/strong\u003e The coating lowers friction for smooth passage through the endoscope channel and the target anatomy.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSoft tip, straight or angled.\u003c\/strong\u003e A super-smooth soft head helps protect tissue during navigation. The angled option makes it easier to select ducts and steer through turns.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTwo-color spiral outer tube.\u003c\/strong\u003e The alternating two-color pattern makes wire movement easy to see on endoscopic view, which helps the clinician track advancement and withdrawal.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSeamless integrated design.\u003c\/strong\u003e The one-piece construction gives a continuous, smooth profile with no transitions that could catch.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eExcellent anti-twisting performance.\u003c\/strong\u003e The wire resists kinking and twisting, so torque transmits reliably and the wire keeps its shape through repeated manipulation.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eUsed with an endoscope to guide into the digestive or urinary tract, or to guide other medical devices into position.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/109-0.032\"\/1500A ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 0.81 mm (0.032\") ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1500 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/109-0.032\"\/1500L ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 0.81 mm (0.032\") ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1500 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/109-0.035\"\/4500A ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 0.89 mm (0.035\") ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 4500 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/109-0.035\"\/4500L ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 0.89 mm (0.035\") ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 4500 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCharacteristics (all models):\u003c\/strong\u003e Super-smooth soft head ┃ Straight or angled tip ┃ Two-color spiral outer tube\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/109GA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/109-0.032\"\/1500A ┃ O.D.: 0.81 mm (0.032\") ┃ Length: 1500 mm","offer_id":67595271438523,"sku":"HMP004-01","price":32.0,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/109-0.032\"\/1500L ┃ O.D.: 0.81 mm (0.032\") ┃ Length: 1500 mm","offer_id":67595271471291,"sku":"HMP004-02","price":32.0,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/109-0.035\"\/4500A ┃ O.D.: 0.89 mm (0.035\") ┃ Length: 4500 mm","offer_id":67595271504059,"sku":"HMP004-03","price":105.0,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/109-0.035\"\/4500L ┃ O.D.: 0.89 mm (0.035\") ┃ Length: 4500 mm","offer_id":67595271536827,"sku":"HMP004-04","price":105.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-29at6.53.31PM.png?v=1790734272"},{"product_id":"health-microport-disposable-balloon-dilatation-catheter","title":"Health Microport Disposable Balloon Dilatation Catheter","description":"\u003ch2 dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Balloon Dilatation Catheter is a single-use endoscopic accessory for treating gastrointestinal stenosis through dilation, and for auxiliary dilation during endoscopic procedures. The balloon is made from high-pressure-resistant material, folds into six wings to pass through a 2.8 mm endoscope channel, and has radiopaque markers for positioning under X-ray.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHigh-pressure-resistant balloon.\u003c\/strong\u003e The balloon material withstands high inflation pressure, so expansion is safe, controlled, and reliable.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSix-wing folding design.\u003c\/strong\u003e The balloon folds into six wings for a low profile. It passes easily through an endoscope working channel of 2.8 mm.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eRadiopaque markers.\u003c\/strong\u003e Markers at the balloon ends show clearly under X-ray, so the balloon can be positioned precisely across the stricture.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e0.035\" guide wire compatible.\u003c\/strong\u003e The catheter is designed for over-the-wire placement with a 0.035\" guide wire.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each catheter is used once. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eDilation treatment of gastrointestinal stenosis, or auxiliary dilation.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/301-0840 ┃ \u003cstrong\u003eBalloon O.D.:\u003c\/strong\u003e 8 mm ┃ \u003cstrong\u003eBalloon Length:\u003c\/strong\u003e 40 mm ┃ \u003cstrong\u003eCatheter Length:\u003c\/strong\u003e 850 1800 2300 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/301-1040 ┃ \u003cstrong\u003eBalloon O.D.:\u003c\/strong\u003e 10 mm ┃ \u003cstrong\u003eBalloon Length:\u003c\/strong\u003e 40 mm ┃ \u003cstrong\u003eCatheter Length:\u003c\/strong\u003e 850 1800 2300 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/301-1240 ┃ \u003cstrong\u003eBalloon O.D.:\u003c\/strong\u003e 12 mm ┃ \u003cstrong\u003eBalloon Length:\u003c\/strong\u003e 40 mm ┃ \u003cstrong\u003eCatheter Length:\u003c\/strong\u003e 850 1800 2300 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/301-1660 ┃ \u003cstrong\u003eBalloon O.D.:\u003c\/strong\u003e 16 mm ┃ \u003cstrong\u003eBalloon Length:\u003c\/strong\u003e 60 mm ┃ \u003cstrong\u003eCatheter Length:\u003c\/strong\u003e 850 1800 2300 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e 2.8 mm ┃ \u003cstrong\u003eGuide Wire:\u003c\/strong\u003e 0.035\"\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/301G4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/301-0840 ┃ Balloon O.D.: 8 mm ┃ Balloon Length: 40 mm ┃ Catheter Length: 850 1800 2300 mm","offer_id":67599303049403,"sku":"HMP004-01","price":197.12,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/301-1040 ┃ Balloon O.D.: 10 mm ┃ Balloon Length: 40 mm ┃ Catheter Length: 850 1800 2300 mm","offer_id":67599303082171,"sku":"HMP004-02","price":197.12,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/301-1240 ┃ Balloon O.D.: 12 mm ┃ Balloon Length: 40 mm ┃ Catheter Length: 850 1800 2300 mm","offer_id":67599303114939,"sku":"HMP004-03","price":197.12,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/301-1660 ┃ Balloon O.D.: 16 mm ┃ Balloon Length: 60 mm ┃ Catheter Length: 850 1800 2300 mm","offer_id":67599303147707,"sku":"HMP004-04","price":197.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-29at7.23.06PM.png?v=1790736202"},{"product_id":"disposable-endoscopic-ligation-device","title":"Health Microport Disposable Endoscopic Ligation Device","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Endoscopic Ligation Device is a single-use endoscopic accessory for band ligation of esophageal varices and internal hemorrhoids. It mounts on the endoscope tip and uses negative-pressure suction to draw target tissue into a transparent cap, then releases natural rubber ligation bands with a rotating handle. No submucosal injection is required.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eNegative-pressure suction.\u003c\/strong\u003e The target tissue is drawn into the cap by suction before banding, so no submucosal injection is needed.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTransparent adsorption cap.\u003c\/strong\u003e The clear cap keeps the ligation area visible, which helps the operator place each band accurately.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eNatural rubber ligation bands.\u003c\/strong\u003e The bands give strong, consistent tightening force for secure ligation.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAdjustable release handle.\u003c\/strong\u003e The handle supports single and bidirectional adjustable release, so the operator controls band deployment.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eClear hemorrhoid exposure.\u003c\/strong\u003e For hemorrhoid ligation in the retroflexed (inverted) endoscope view, the design exposes the hemorrhoid location more clearly.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMultiple band counts.\u003c\/strong\u003e Configurations with 4, 5, 6, or 7 bands cover different procedure needs.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eFor use by clinical units with endoscopes for ligation of esophageal varices or internal hemorrhoids.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/105-4-A ┃ \u003cstrong\u003eLigation Bands:\u003c\/strong\u003e 4 ┃ \u003cstrong\u003eEndoscope Tip Diameter:\u003c\/strong\u003e 9.5–10 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/105-5-A ┃ \u003cstrong\u003eLigation Bands:\u003c\/strong\u003e 5 ┃ \u003cstrong\u003eEndoscope Tip Diameter:\u003c\/strong\u003e 9.5–10 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/105-6-A ┃ \u003cstrong\u003eLigation Bands:\u003c\/strong\u003e 6 ┃ \u003cstrong\u003eEndoscope Tip Diameter:\u003c\/strong\u003e 9.5–10 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/105-7-A ┃ \u003cstrong\u003eLigation Bands:\u003c\/strong\u003e 7 ┃ \u003cstrong\u003eEndoscope Tip Diameter:\u003c\/strong\u003e 9.5–10 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePackage Contents (each unit):\u003c\/strong\u003e Transparent adsorption cap with preloaded ligation bands ┃ Release device\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eLatex Notice:\u003c\/strong\u003e Contains natural rubber latex\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/105G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/105-4-A ┃ Ligation Bands: 4 ┃ Endoscope Tip Diameter: 9.5–10 mm","offer_id":67602325209275,"sku":"HMP006-01","price":150.0,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/105-5-A ┃ Ligation Bands: 5 ┃ Endoscope Tip Diameter: 9.5–10 mm","offer_id":67602325242043,"sku":"HMP006-02","price":160.0,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/105-6-A ┃ Ligation Bands: 6 ┃ Endoscope Tip Diameter: 9.5–10 mm","offer_id":67602325274811,"sku":"HMP006-03","price":177.59,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/105-7-A ┃ Ligation Bands: 7 ┃ Endoscope Tip Diameter: 9.5–10 mm","offer_id":67602325307579,"sku":"HMP006-04","price":177.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at8.54.37AM.png?v=1790783858"},{"product_id":"disposable-grasping-forceps-tooth-shape","title":"Health Microport Disposable Grasping Forceps (Tooth Shape)","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Grasping Forceps are a single-use endoscopic accessory for grasping and removing foreign bodies from the alimentary tract, used together with an endoscope. Three toothed jaw designs are available (alligator, rat tooth alligator, and gannet mouth) to suit foreign objects of different shapes and sizes. Versions are offered for gastroscopes and enteroscopes.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMultiple jaw designs.\u003c\/strong\u003e Alligator, rat tooth alligator, and gannet mouth jaws give the clinician options for different foreign body shapes, sizes, and textures.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSmooth, flat tip.\u003c\/strong\u003e The rounded, flat tip profile helps protect the endoscope channel and surrounding tissue during insertion and manipulation.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eBiocompatible materials.\u003c\/strong\u003e The forceps are made from biocompatible materials suitable for contact with the alimentary tract.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each device is used once. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eGrasping and removing foreign bodies from the human alimentary tract, used with an endoscope.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAlligator Jaw\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600A2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300A2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eRat Tooth Alligator Jaw\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600A3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300A3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1800A3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.0 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eGannet Mouth Jaw\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600A4 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300A4 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.3 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/108G8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Alligator Jaw | Model Number: HM\/108-2.3\/1600A2 ┃ O.D.: 2.3 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602508939451,"sku":"HMP007-01","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"Alligator Jaw | Model Number: HM\/108-2.3\/2300A2 ┃ O.D.: 2.3 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602508972219,"sku":"HMP007-02","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"Rat Tooth Alligator | Model Number: HM\/108-2.3\/1600A3 ┃ O.D.: 2.3 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602509004987,"sku":"HMP007-03","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"Rat Tooth Alligator | Model Number: HM\/108-2.3\/2300A3 ┃ O.D.: 2.3 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602509037755,"sku":"HMP007-04","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"Rat Tooth Alligator | Model Number: HM\/108-1.8\/1800A3 ┃ O.D.: 1.8 mm ┃ Length: 1800 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.0 mm","offer_id":67602509070523,"sku":"HMP007-05","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"Gannet Mouth | Model Number: HM\/108-2.3\/1600A4 ┃ O.D.: 2.3 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602509103291,"sku":"HMP007-06","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"Gannet Mouth | Model Number: HM\/108-2.3\/2300A4 ┃ O.D.: 2.3 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602509136059,"sku":"HMP007-07","price":26.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at9.36.09AM.png?v=1790788320"},{"product_id":"health-microport-disposable-grasping-forceps-claw-shaped","title":"Health Microport Disposable Grasping Forceps (Claw Shaped)","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Grasping Forceps (Claw Shaped) are a single-use endoscopic accessory for grasping and removing foreign bodies from the alimentary tract, used together with an endoscope. The flexible metal wire prongs come in 3-, 4-, and 5-prong configurations to hold foreign objects of different shapes and sizes. Versions are offered for gastroscopes and enteroscopes.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMetal wire prongs.\u003c\/strong\u003e The wire claw creates strong friction against the object, so foreign bodies are grasped accurately and held firmly during withdrawal.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eGood elasticity and high strength.\u003c\/strong\u003e The prongs flex to conform around irregular objects and keep their shape and holding force.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e3-, 4-, and 5-prong options.\u003c\/strong\u003e Different prong counts let the clinician match the claw to the size, shape, and weight of the foreign body.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each device is used once. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eGrasping and removing foreign bodies from the human alimentary tract, used with an endoscope.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e3-Prong Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600B1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300B1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1800B1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.0 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e4-Prong Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600B2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300B2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1800B2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.0 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e5-Prong Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600B3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300B3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/108G8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"3-Prong Type ┃ Model Number: HM\/108-2.3\/1600B1 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602686640315,"sku":"HMP008-01","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"3-Prong Type ┃ Model Number: HM\/108-2.3\/2300B1 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602686673083,"sku":"HMP008-02","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"3-Prong Type ┃ Model Number: HM\/108-1.8\/1800B1 ┃ O.D.: 1.8 mm ┃ Length: 1800 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.0 mm","offer_id":67602686705851,"sku":"HMP008-03","price":37.98,"currency_code":"EUR","in_stock":true},{"title":"4-Prong Type ┃ Model Number: HM\/108-2.3\/1600B2 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602686738619,"sku":"HMP008-04","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"4-Prong Type ┃ Model Number: HM\/108-2.3\/2300B2 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602686771387,"sku":"HMP008-05","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"4-Prong Type ┃ Model Number: HM\/108-1.8\/1800B2 ┃ O.D.: 1.8 mm ┃ Length: 1800 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.0 mm","offer_id":67602686804155,"sku":"HMP008-06","price":37.98,"currency_code":"EUR","in_stock":true},{"title":"5-Prong Type ┃ Model Number: HM\/108-2.3\/1600B3 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602686836923,"sku":"HMP008-07","price":26.64,"currency_code":"EUR","in_stock":true},{"title":"5-Prong Type ┃ Model Number: HM\/108-2.3\/2300B3 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602686869691,"sku":"HMP008-08","price":26.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at10.32.23AM.png?v=1790790226"},{"product_id":"health-microport-disposable-grasping-forceps-snare","title":"Health Microport Disposable Grasping Forceps (Snare)","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Grasping Forceps (Snare) are a single-use endoscopic accessory for grasping and removing foreign bodies from the alimentary tract, used together with an endoscope. The snare loop is made from high-strength stainless steel wire rope. Oval, crescent, and hexagonal loop shapes are available to capture foreign objects of different shapes and sizes, and versions are offered for gastroscopes and enteroscopes.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHigh-strength stainless steel wire rope.\u003c\/strong\u003e The loop is made from imported medical-grade stainless steel wire rope that stays elastic, so it opens reliably and closes securely around the object.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e360° reversible rotation.\u003c\/strong\u003e The loop can be rotated in either direction to orient it precisely around the foreign body before capture.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThree loop shapes.\u003c\/strong\u003e Oval, crescent, and hexagonal loops let the clinician match the snare to the size and shape of the foreign body.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each device is used once. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eGrasping and removing foreign bodies from the human alimentary tract, used with an endoscope.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOval\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600C1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOval\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300C1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOval\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1800C1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.0 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCrescent\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600C2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCrescent\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300C2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHexagonal\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600C3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHexagonal\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300C3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Enteroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHexagonal\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1800C3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eEndoscope:\u003c\/strong\u003e Gastroscope ┃ \u003cstrong\u003eMin. Channel:\u003c\/strong\u003e 2.0 mm\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/108G8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Oval ┃ Model Number: HM\/108-2.3\/1600C1 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602708660411,"sku":"HMP009-01","price":23.19,"currency_code":"EUR","in_stock":true},{"title":"Oval ┃ Model Number: HM\/108-2.3\/2300C1 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602708693179,"sku":"HMP009-02","price":23.19,"currency_code":"EUR","in_stock":true},{"title":"Oval ┃ Model Number: HM\/108-1.8\/1800C1 ┃ O.D.: 1.8 mm ┃ Length: 1800 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.0 mm","offer_id":67602708725947,"sku":"HMP009-03","price":23.19,"currency_code":"EUR","in_stock":true},{"title":"Crescent ┃ Model Number: HM\/108-2.3\/1600C2 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602708758715,"sku":"HMP009-04","price":28.0,"currency_code":"EUR","in_stock":true},{"title":"Crescent ┃ Model Number: HM\/108-2.3\/2300C2 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602708791483,"sku":"HMP009-05","price":28.0,"currency_code":"EUR","in_stock":true},{"title":"Hexagonal ┃ Model Number: HM\/108-2.3\/1600C3 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.8 mm","offer_id":67602708824251,"sku":"HMP009-06","price":23.19,"currency_code":"EUR","in_stock":true},{"title":"Hexagonal ┃ Model Number: HM\/108-2.3\/2300C3 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Endoscope: Enteroscope ┃ Min. Channel: 2.8 mm","offer_id":67602708857019,"sku":"HMP009-07","price":23.19,"currency_code":"EUR","in_stock":true},{"title":"Hexagonal ┃ Model Number: HM\/108-1.8\/1800C3 ┃ O.D.: 1.8 mm ┃ Length: 1800 mm ┃ Endoscope: Gastroscope ┃ Min. Channel: 2.0 mm","offer_id":67602708889787,"sku":"HMP009-08","price":23.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at11.19.41AM_4112f576-c75f-4597-8a21-6acde036a70a.png?v=1790792852"},{"product_id":"health-microport-disposable-grasping-forceps-basket","title":"Health Microport Disposable Grasping Forceps (Basket)","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Grasping Forceps (Basket) are a single-use endoscopic accessory for grasping and removing foreign bodies from the alimentary tract, used together with an endoscope. They're especially suited to smooth or slippery objects, because the basket can be pulled back into its sheath to tighten around the object. Tipless, diamond, and net-pocket basket designs are available, in nitinol or stainless steel.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSecure capture of slippery objects.\u003c\/strong\u003e The basket retracts into its sheath to close firmly around smooth or slippery foreign bodies that are hard to hold with a forceps or snare.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHigh firmness.\u003c\/strong\u003e The basket structure keeps its shape under load, which improves the retrieval success rate.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSynchronous 360° bidirectional rotation.\u003c\/strong\u003e The basket rotates in either direction to align with the foreign body before capture.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eNylon mesh pocket (net type).\u003c\/strong\u003e The net version adds a nylon mesh pocket that contains small or fragmented objects during withdrawal.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThree basket designs.\u003c\/strong\u003e Tipless (nitinol), diamond (stainless steel), and net-pocket (nitinol) designs let the clinician match the basket to the object and the anatomy.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each device is used once. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eGrasping and removing foreign bodies from the human alimentary tract, used with an endoscope.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTipless\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1200D1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1200 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Nitinol ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.0 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTipless\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1600D1 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Nitinol ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.0 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDiamond\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600D2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Stainless Steel Wire Rope ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDiamond\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300D2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Stainless Steel Wire Rope ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDiamond\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1800D2 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Stainless Steel Wire Rope ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.0 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWith Net\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/1600D3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Nitinol ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWith Net\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-2.3\/2300D3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 2.4 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2300 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Nitinol ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.8 mm\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWith Net\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/108-1.8\/1800D3 ┃ \u003cstrong\u003eO.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eMaterial:\u003c\/strong\u003e Nitinol ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.0 mm\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/108G8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Tipless ┃ Model Number: HM\/108-1.8\/1200D1 ┃ O.D.: 1.8 mm ┃ Length: 1200 mm ┃ Material: Nitinol ┃ Endoscope Channel: ≥2.0 mm","offer_id":67603515867323,"sku":"HMP011-01","price":55.25,"currency_code":"EUR","in_stock":true},{"title":"Tipless ┃ Model Number: HM\/108-1.8\/1600D1 ┃ O.D.: 1.8 mm ┃ Length: 1600 mm ┃ Material: Nitinol ┃ Endoscope Channel: ≥2.0 mm","offer_id":67603515900091,"sku":"HMP011-02","price":55.25,"currency_code":"EUR","in_stock":true},{"title":"Diamond ┃ Model Number: HM\/108-2.3\/1600D2 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Material: Stainless Steel Wire Rope ┃ Endoscope Channel: ≥2.8 mm","offer_id":67603515932859,"sku":"HMP011-03","price":37.0,"currency_code":"EUR","in_stock":true},{"title":"Diamond ┃ Model Number: HM\/108-2.3\/2300D2 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Material: Stainless Steel Wire Rope ┃ Endoscope Channel: ≥2.8 mm","offer_id":67603515965627,"sku":"HMP011-04","price":37.0,"currency_code":"EUR","in_stock":true},{"title":"Diamond ┃ Model Number: HM\/108-1.8\/1800D2 ┃ O.D.: 1.8 mm ┃ Length: 1800 mm ┃ Material: Stainless Steel Wire Rope ┃ Endoscope Channel: ≥2.0 mm","offer_id":67603515998395,"sku":"HMP011-05","price":37.0,"currency_code":"EUR","in_stock":true},{"title":"With Net ┃ Model Number: HM\/108-2.3\/1600D3 ┃ O.D.: 2.4 mm ┃ Length: 1600 mm ┃ Material: Nitinol ┃ Endoscope Channel: ≥2.8 mm","offer_id":67603516031163,"sku":"HMP011-06","price":48.34,"currency_code":"EUR","in_stock":true},{"title":"With Net ┃ Model Number: HM\/108-2.3\/2300D3 ┃ O.D.: 2.4 mm ┃ Length: 2300 mm ┃ Material: Nitinol ┃ Endoscope Channel: ≥2.8 mm","offer_id":67603516063931,"sku":"HMP011-07","price":48.34,"currency_code":"EUR","in_stock":true},{"title":"With Net ┃ Model Number: HM\/108-1.8\/1800D3 ┃ O.D.: 1.8 mm ┃ Length: 1800 mm ┃ Material: Nitinol ┃ Endoscope Channel: ≥2.0 mm","offer_id":67603516096699,"sku":"HMP011-08","price":37.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at11.46.12AM.png?v=1790794251"},{"product_id":"health-microport-disposable-cytology-brush","title":"Health Microport Disposable Cytology Brush","description":"\u003cp\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Disposable Cytology Brush is a single-use endoscopic accessory for collecting cell and tissue samples during clinical procedures. It has a rounded atraumatic tip, an integrated brush head with bristles of balanced stiffness, and a smooth outer sheath that protects the endoscope channel. Sizes are available for endoscope channels from 1.2 mm to 2.8 mm and larger.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRounded atraumatic tip.\u003c\/strong\u003e The round head end protects tissue during insertion and sampling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBalanced bristle stiffness.\u003c\/strong\u003e The bristles are firm enough to collect cells effectively and gentle enough for easy, comfortable sampling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated brush head.\u003c\/strong\u003e The one-piece brush construction keeps the head secure and consistent during use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmooth protective outer sheath.\u003c\/strong\u003e The smooth sheath protects both the brush and the endoscope working channel during insertion and withdrawal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each brush is used once. This removes the need for reprocessing and lowers the risk of sample contamination and cross-contamination between patients.\u003c\/p\u003e\n\u003ch3\u003eIntended Use\u003c\/h3\u003e\n\u003cp\u003eFor clinical collection of cell and tissue samples.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/102-12\/1200Z ┃ \u003cstrong\u003eSheath O.D.:\u003c\/strong\u003e 1.0 mm ┃ \u003cstrong\u003eBrush Head O.D.:\u003c\/strong\u003e 1.2 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1200 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥1.2 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/102-20\/1050Z ┃ \u003cstrong\u003eSheath O.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eBrush Head O.D.:\u003c\/strong\u003e 2.0 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1050 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.0 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/102-20\/1200Z ┃ \u003cstrong\u003eSheath O.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eBrush Head O.D.:\u003c\/strong\u003e 2.0 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1200 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.0 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/102-50\/1600Z ┃ \u003cstrong\u003eSheath O.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eBrush Head O.D.:\u003c\/strong\u003e 5.0 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1600 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.8 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/102-50\/1800Z ┃ \u003cstrong\u003eSheath O.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eBrush Head O.D.:\u003c\/strong\u003e 5.0 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 1800 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.8 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/102-50\/2200Z ┃ \u003cstrong\u003eSheath O.D.:\u003c\/strong\u003e 1.8 mm ┃ \u003cstrong\u003eBrush Head O.D.:\u003c\/strong\u003e 5.0 mm ┃ \u003cstrong\u003eLength:\u003c\/strong\u003e 2200 mm ┃ \u003cstrong\u003eEndoscope Channel:\u003c\/strong\u003e ≥2.8 mm\u003c\/p\u003e\n\u003ch3\u003eRegulatory Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/102FU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/102-12\/1200Z ┃ Sheath O.D.: 1.0 mm ┃ Brush Head O.D.: 1.2 mm ┃ Length: 1200 mm ┃ Endoscope Channel: ≥1.2 mm","offer_id":67604278476987,"sku":"HMP012-001","price":22.45,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/102-20\/1050Z ┃ Sheath O.D.: 1.8 mm ┃ Brush Head O.D.: 2.0 mm ┃ Length: 1050 mm ┃ Endoscope Channel: ≥2.0 mm","offer_id":67604278509755,"sku":"HMP012-002","price":12.65,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/102-20\/1200Z ┃ Sheath O.D.: 1.8 mm ┃ Brush Head O.D.: 2.0 mm ┃ Length: 1200 mm ┃ Endoscope Channel: ≥2.0 mm","offer_id":67604278542523,"sku":"HMP012-003","price":12.65,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/102-50\/1600Z ┃ Sheath O.D.: 1.8 mm ┃ Brush Head O.D.: 5.0 mm ┃ Length: 1600 mm ┃ Endoscope Channel: ≥2.8 mm","offer_id":67604278575291,"sku":"HMP012-004","price":12.65,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/102-50\/1800Z ┃ Sheath O.D.: 1.8 mm ┃ Brush Head O.D.: 5.0 mm ┃ Length: 1800 mm ┃ Endoscope Channel: ≥2.8 mm","offer_id":67604278608059,"sku":"HMP012-005","price":12.65,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/102-50\/2200Z ┃ Sheath O.D.: 1.8 mm ┃ Brush Head O.D.: 5.0 mm ┃ Length: 2200 mm ┃ Endoscope Channel: ≥2.8 mm","offer_id":67604278640827,"sku":"HMP012-006","price":12.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at3.53.46PM.png?v=1790808860"},{"product_id":"health-microport-hemorrhoidal-multi-band-ligator-with-anoscope","title":"Health Microport Hemorrhoidal Multi-Band Ligator with Anoscope","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class IIa) | EUDAMED Registered | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Hemorrhoidal Multi-Band Ligator with Anoscope is a single-use device for rubber band ligation of internal hemorrhoids in adults. It's used together with the included anoscope, and the ligation bands come preloaded, so multiple hemorrhoids can be banded in one session without reloading. Sets are available with 4 or 5 bands.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePreloaded ligation bands.\u003c\/strong\u003e The bands come installed in advance, so the device is ready to use with no loading step.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMulti-band design.\u003c\/strong\u003e Four or five bands per device allow several hemorrhoids to be treated in one procedure without reloading.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIncluded anoscope.\u003c\/strong\u003e Each set comes with an anoscope for clear access to and visualization of the treatment site.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTime-saving and easy to use.\u003c\/strong\u003e The ergonomic handle and preloaded design reduce procedure time and operator effort.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSingle-use design.\u003c\/strong\u003e Each set is used for one patient. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eUsed with an anoscope for ligation of internal hemorrhoids in adults only.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/601-5-B ┃ \u003cstrong\u003eLigation Bands:\u003c\/strong\u003e 5 ┃ \u003cstrong\u003eIncludes:\u003c\/strong\u003e 1 Anoscope\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/601-4-B ┃ \u003cstrong\u003eLigation Bands:\u003c\/strong\u003e 4 ┃ \u003cstrong\u003eIncludes:\u003c\/strong\u003e 1 Anoscope\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/601GK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Model Number: HM\/601-5-B ┃ Ligation Bands: 5 ┃ Includes: 1 Anoscope","offer_id":67605522546875,"sku":"HMP013-01","price":83.86,"currency_code":"EUR","in_stock":true},{"title":"Model Number: HM\/601-4-B ┃ Ligation Bands: 4 ┃ Includes: 1 Anoscope","offer_id":67605522579643,"sku":"HMP013-02","price":83.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at3.39.35PM.png?v=1790808152"},{"product_id":"health-microport-disposable-biopsy-valve","title":"Health Microport Disposable Biopsy Valve-Suitable for Olympus\/Pentax Endoscopes","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class I Sterile) | EUDAMED Registered | Sterile | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Biopsy Valve is a sterile, single-use endoscopic accessory that fits on the biopsy channel port of the endoscope to prevent backflow of body fluids during procedures. It's made from soft TPE and is compatible with Olympus and Pentax endoscopes. Versions are available with or without a connecting tube.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSoft TPE material.\u003c\/strong\u003e The flexible thermoplastic elastomer seals securely around instruments while allowing smooth insertion and withdrawal.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eBackflow prevention.\u003c\/strong\u003e The valve seals the endoscope channel opening to prevent reverse flow of body fluids, which helps keep the procedure area clean.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOlympus and Pentax compatibility.\u003c\/strong\u003e Dedicated versions fit Olympus and Pentax endoscope channel ports.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWith or without tube.\u003c\/strong\u003e Tube-equipped versions are available for connection to additional accessories.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIndividually sterile-packed.\u003c\/strong\u003e Each valve is sterile-packed separately for single use. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eUsed at the endoscope channel opening to prevent reverse flow of body fluids.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOlympus – Without Tube\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/801-O-A ┃ \u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually sterile-packed \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePentax – Without Tube\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/801-P-A ┃ \u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually sterile-packed \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOlympus – With Tube\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/801-O-B ┃ \u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually sterile-packed \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePentax – With Tube\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/801-P-B ┃ \u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually sterile-packed \u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I (sterile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/801GV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197), for aspects of manufacture concerned with sterility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eOlympus and Pentax are trademarks of their respective owners. This product is not manufactured by or affiliated with Olympus or Pentax.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"Olympus – Without Tube ┃ Model Number: HM\/801-O-A ┃ Packaging: Individually sterile-packed","offer_id":67605537226939,"sku":"HMP014-01","price":1.8,"currency_code":"EUR","in_stock":true},{"title":"Pentax – Without Tube ┃ Model Number: HM\/801-P-A ┃ Packaging: Individually sterile-packed","offer_id":67605537259707,"sku":"HMP014-02","price":1.8,"currency_code":"EUR","in_stock":true},{"title":"Olympus – With Tube ┃ Model Number: HM\/801-O-B ┃ Packaging: Individually sterile-packed","offer_id":67605537292475,"sku":"HMP014-03","price":4.5,"currency_code":"EUR","in_stock":true},{"title":"Pentax – With Tube ┃ Model Number: HM\/801-P-B ┃ Packaging: Individually sterile-packed","offer_id":67605537325243,"sku":"HMP014-04","price":4.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at4.27.55PM.png?v=1790811193"},{"product_id":"health-microport-disposable-multi-chamber-polyp-trap","title":"Health Microport Disposable Multi-Chamber Polyp Trap","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCE Marked (Class I Sterile) | EUDAMED Registered | Sterile | Single Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Disposable Multi-Chamber Polyp Trap is a sterile, single-use accessory that simplifies polyp collection and improves specimen handling during colonoscopy. It connects to the suction line, and its fine-mesh screen captures even small polyps. Numbered, individually removable chambers keep multiple specimens separate, so each can be labeled and sent for pathology.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eKey Features\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFine-mesh screen.\u003c\/strong\u003e The fine filter captures small polyps and tissue fragments reliably.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMultiple removable chambers.\u003c\/strong\u003e Four or five individually removable chambers collect separate specimens in a single procedure.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eClear position indicators.\u003c\/strong\u003e Each chamber is clearly numbered, so specimens can be matched to their collection sites.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eVisual verification.\u003c\/strong\u003e The transparent housing lets the clinician confirm that a polyp has been collected.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSealing cover.\u003c\/strong\u003e A sealing cover protects collected specimens from contamination.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIndividually sterile-packed.\u003c\/strong\u003e Each trap is sterile-packed separately for single use. This removes the need for reprocessing and lowers the risk of cross-contamination between patients.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eIntended Use\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eCollection of polyps and colonoscopy specimens.\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eSpecifications\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e5-Chamber\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/802-1 ┃ \u003cstrong\u003eChambers:\u003c\/strong\u003e 5 individually removable ┃ \u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually sterile-packed \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e4-Chamber\u003c\/strong\u003e ┃ \u003cstrong\u003eModel Number:\u003c\/strong\u003e HM\/802-2 ┃ \u003cstrong\u003eChambers:\u003c\/strong\u003e 4 individually removable ┃ \u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually sterile-packed \u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003eRegulatory Information\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I (sterile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic UDI-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69518622HM\/802GX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotified Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV Rheinland LGA Products GmbH (NB 0197), for aspects of manufacture concerned with sterility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Certificate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHD 60147762 0001 (Directive 93\/42\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMDR Transition Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValidity extended under Article 120 of Regulation (EU) 2017\/745, as amended by Regulation (EU) 2023\/607. The Notified Body has confirmed the formal MDR application and written agreement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Validity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUntil December 31, 2028, subject to the conditions of Article 120(3c) MDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUDAMED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegistered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cem\u003eFor professional use only. Sold exclusively to hospitals, clinics, and other licensed healthcare institutions. Read the Instructions for Use before use.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eWarranty Policy\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMedaza Europe, d.o.o.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProduct Scope\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is intended solely for use by licensed clinics, hospitals, laboratories, and research facilities within the European Union \/ European Economic Area, for professional or institutional use by licensed medical professionals. It is not labeled, marketed, or warranted for consumer or home use, and is not intended for resale to individual end users.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimited Manufacturer Warranty\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis product is warranted by the original manufacturer to be free from defects in materials and workmanship at the time of shipment, when stored, handled, and used in accordance with the manufacturer's Instructions for Use (IFU) and labeling.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSingle-Use \/ Consumable Exclusion\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis is a single-use, sterile medical consumable intended for one-time use. As a consumable product, it is:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eNot covered by any warranty once the sterile packaging has been opened, the product has been used, or the expiration\/use-by date has passed\u003c\/li\u003e\n\u003cli\u003eNot eligible for return, replacement, or refund based on buyer's change of mind, over-ordering, or discontinued use, once shipped and accepted\u003c\/li\u003e\n\u003cli\u003eExcluded from any implied warranty of merchantability or fitness for a particular purpose beyond what is required by applicable law, including any statutory conformity rights the Buyer may hold under national implementations of EU consumer or commercial law where applicable to institutional purchasers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat IS Covered\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eNotwithstanding the section above, this warranty does apply, and Medaza Europe, d.o.o. will facilitate a replacement, credit, or refund, coordinating with the manufacturer as needed, where:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eThe product arrives with compromised sterile packaging (torn, punctured, or improperly sealed) at time of receipt\u003c\/li\u003e\n\u003cli\u003eThe product exhibits a manufacturing defect present prior to use (e.g., material failure, dimensional nonconformity, malfunction not attributable to misuse, improper storage, or mishandling by buyer)\u003c\/li\u003e\n\u003cli\u003eThe product was not as described on the invoice or packing slip (wrong configuration, size, or gauge shipped in error)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eClaims under this section must be submitted within 3 business days of receipt (unopened packaging defects) or promptly upon discovery of a manufacturing defect, and must include lot number, photographs, and a description of the issue. Medaza Europe, d.o.o. reserves the right to require return of the affected unit(s) for manufacturer inspection prior to issuing replacement or credit.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eExclusions\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis warranty does not cover damage or nonconformity resulting from:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eImproper storage (e.g., temperature excursion, exposure to moisture or contaminants)\u003c\/li\u003e\n\u003cli\u003eUse beyond the labeled expiration date\u003c\/li\u003e\n\u003cli\u003eImproper handling, technique, or clinical misuse\u003c\/li\u003e\n\u003cli\u003eAlteration or modification of the product by buyer or any third party\u003c\/li\u003e\n\u003cli\u003eNormal wear expected in single-use consumables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eField Safety Corrective Actions and Recalls\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eIn the event the manufacturer, Medaza Europe, d.o.o., or an authorized regulatory body (including but not limited to a national Competent Authority such as JAZMP, or another EU\/EEA Competent Authority) issues a recall, Field Safety Notice, or Field Safety Corrective Action (FSCA) affecting this product, in accordance with MDR Articles 87–92:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eMedaza Europe, d.o.o. will notify affected buyers using the contact and shipment records on file, relying on lot\/batch traceability and UDI records maintained under Medaza Europe, d.o.o.'s Quality Management System\u003c\/li\u003e\n\u003cli\u003eBuyers are required to immediately quarantine and cease use of any affected lots upon notification, and to cooperate with return, disposition, or reporting instructions provided\u003c\/li\u003e\n\u003cli\u003eBuyers must report any serious incidents or product complaints associated with this product to Medaza Europe, d.o.o. promptly, so that Medaza Europe, d.o.o. can fulfill its complaint-handling and vigilance obligations to the manufacturer and, where applicable, to the relevant Competent Authority and\/or EUDAMED\u003c\/li\u003e\n\u003cli\u003eParticipation in a recall or FSCA does not waive, and is separate from, the warranty terms above — recalled product is addressed under recall\/vigilance procedures, not warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eImporter and Distributor Role\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor this product, Medaza Europe, d.o.o. acts as both \u003cstrong\u003eimporter\u003c\/strong\u003e under MDR Article 13 and \u003cstrong\u003edistributor\u003c\/strong\u003e under MDR Article 14. As importer, Medaza Europe, d.o.o. confirms it has verified that the manufacturer has carried out the applicable conformity assessment procedure, that the product bears the required CE marking and UDI, that the manufacturer has designated an authorized representative where required, and that the product is accompanied by the manufacturer's required labeling and Instructions for Use. Medaza Europe, d.o.o. further confirms it maintains appropriate storage and transport conditions for the product while it is under its responsibility, in accordance with the manufacturer's specifications. This warranty does not alter or diminish those statutory importer and distributor obligations.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eLimitation of Liability\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eExcept as expressly stated above, this product is provided on an \"as-is\" basis to the extent permitted by applicable law. Medaza Europe, d.o.o.'s liability under this warranty is limited to replacement, credit, or refund of the affected unit(s), and Medaza Europe, d.o.o. is not liable for indirect, incidental, or consequential damages arising from use of this product.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eGoverning Terms\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThis Warranty Policy operates alongside, and does not limit, Medaza Europe, d.o.o.'s Terms of Service, Privacy Policy (in accordance with Regulation (EU) 2016\/679, the GDPR), Shipping Policy, and applicable human medical device regulatory obligations under Regulation (EU) 2017\/745 (MDR), JAZMP, and EUDAMED registration and reporting frameworks, including, where applicable, CE marking and Declaration of Conformity requirements.\u003c\/p\u003e","brand":"Health Microport Endoscopic Accessories","offers":[{"title":"5-Chamber ┃ Model Number: HM\/802-1 ┃ Chambers: 5 individually removable ┃ Packaging: Individually sterile-packed","offer_id":67605542371515,"sku":"HMP015-01","price":6.0,"currency_code":"EUR","in_stock":true},{"title":"4-Chamber ┃ Model Number: HM\/802-2 ┃ Chambers: 4 individually removable ┃ Packaging: Individually sterile-packed","offer_id":67605542404283,"sku":"HMP015-02","price":6.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/files\/Screenshot2026-09-30at4.45.09PM.png?v=1790812006"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/9040\/3515\/collections\/Screenshot_2026-09-22_at_8.00.38_PM.png?v=1790810173","url":"https:\/\/eu.medaza-platform.com\/collections\/endoscopic-accessories.oembed","provider":"Medaza Europe ","version":"1.0","type":"link"}